FAQ: Frequently Asked Questions – Purlin & Side Rails

This page answers common questions about Purlin & Side Rails, covering performance, testing, compliance and design considerations. It also highlights important factors that are often overlooked, helping project teams make informed decisions throughout the construction process.

A list of acronyms/terminology can also be found here.

General

Metsec manufactures:

  • Z purlins
  • C purlins
  • Side rails
  • Eaves beams
  • Mezzanine floor systems

These systems are designed to work together as a complete building envelope solution.

Purlins are horizontal secondary steel members used in roof construction to support roof sheeting or cladding and transfer loads back to the primary steel frame. Side rails perform a similar function in wall construction, supporting wall cladding and transferring wind and other applied loads back to the main structure.

Steel purlins offer:

  • High strength-to-weight ratios
  • Long spans
  • Reduced structural weight
  • Faster installation
  • Offsite manufacturing accuracy
  • Full recyclability
  • Consistent quality
  • Compatibility with modern cladding systems

Metsec systems can achieve spans up to 16m depending on project requirements and system selection.

Yes. Metsec can supply a range of complementary accessories for purlin and side rail systems, including cleats, sag bars, sleeves, anti-sag components and other standard connection items required to complete the system.

Metsec cold-formed steel purlin systems are typically used as secondary steelwork in roof, wall and mezzanine floor construction. Typical applications include supporting roof sheeting or cladding, forming side rail systems for wall cladding, eaves beam applications, and mezzanine floor joist systems. The systems are suitable for a wide range of developments and can be designed for standard or bespoke project requirements, with sections supplied pre-punched and cut to length for efficient site installation.

Yes. Metsec purlin and side rail systems can accommodate a wide range of roof and wall cladding types, subject to appropriate design, restraint and fixing requirements. Side rail systems can be used with horizontal cladding, vertical built-up cladding and vertical composite panels, with additional components such as panel joint rails, horizontal cladding supports and vertical cladding restraint components where required. Project-specific compatibility should be confirmed against the cladding manufacturer’s fixing requirements and the Metsec design.

Technical Specifications

Metsec purlins are C and Z profile studs which range from 142mm to 402mm deep, and are formed from steel 1.3mm-3.0mm gauge (thickness).

Full details of the section range are available on the Metsec Website.

Metsec sections are primarily manufactured from pre-hot dipped galvanised steel with a minimum yield strength of 450N/mm2.

Metsec purlin sections are manufactured from pre-hot dipped galvanised steel with Z275 coating. Z275 coating means 275 grams of zinc per square metre summed over both faces of the steel strip, this corresponds to approximately 0.02mm overall thickness of zinc per face. A reduced range of sections are also available with a thicker Z600 coating, or alternative zinc-magnesium (ZM) coating.

Yes. Metsec provides structural load tables and span information for its purlin, side rail and eaves beam systems. These tables are based on design and testing, with performance derived by calculation to BS EN 1993-1-3 and calibrated by full-scale testing. The published load tables cover common purlin and side rail arrangements and are intended to support preliminary section selection and engineering design checks.

For more detailed project-specific design, Metsec also offers MetSPEC 14 design software, which helps engineers design and optimise purlin roof systems, side rails and mezzanine floor joists. Engineers should confirm final member selection, loading, deflection limits, restraint assumptions and fixing requirements against the full project design.

Metsec purlin and side rail sections are normally supplied to site pre-punched and cut to length, ready for installation. Standard hole positions and typical fixing details are available on the Metsec website, including general detailing information for Z and C sections. This helps reduce site drilling, improves installation consistency and supports accurate coordination with cleats, sleeves, side rail supports and other system accessories.

Any additional or non-standard holes should be confirmed during the project detailing process. Site drilling should only be used where it is permitted by the project design and does not compromise the section, connection or corrosion protection requirements.

EN 1090 is the European standard covering the conformity assessment and execution requirements for structural steel and aluminium components used in construction. For purlins, side rails and associated accessories, it matters because these products form part of the structural load path of the building envelope and must be manufactured under appropriate factory production control, with the correct conformity marking, traceability and declared performance.

Metsec purlins and side rails are individually marked with CE and UKCA conformity marks and barcoded for traceability through the manufacturing process. This gives engineers, contractors and specifiers confidence that the products have been manufactured within a certified process and can be specified in line with the project’s required Execution Class, design assumptions and compliance obligations.

Execution Class 4, or EXC4, is the highest execution class defined under EN 1090 for the execution of steel and aluminium structures. It applies where the consequences of structural failure are particularly high and where enhanced levels of manufacturing control, inspection, traceability and quality assurance are required.

For most purlin and side rail applications, lower execution classes are typically appropriate, subject to the project specification and the requirements of the structural design. However, Metsec’s manufacturing processes are certified up to EXC4, providing assurance that appropriate quality management and production controls are in place where higher execution requirements are specified.

Installation & Construction

Yes. Metsec provides standard construction details and typical fixing arrangements for its purlin and side rail systems, including common details for purlins, side rails, eaves beams, sleeves, cleats, anti-sag systems and related accessories.

These details are available from the Metsec website and are intended to support design coordination, detailing and installation planning. Project-specific fixing requirements, hole positions, restraint assumptions, cladding interfaces and any non-standard details should be confirmed by the project designer or engineer before installation.

Durability & Maintenance

The galvanised zinc coating protects the steel in two ways. First, it acts as a physical barrier, limiting contact between the steel, moisture and oxygen. Secondly, zinc is sacrificial to steel, so at small scratches, cut edges or fixing penetrations the surrounding zinc corrodes preferentially, helping to protect the exposed steel. Durability remains dependent on the coating thickness, exposure conditions and effective control of moisture ingress or condensation.

Compliance & Certification

The Building Safety Act places greater emphasis on competence, traceability and accountable evidence. Metframe supports these requirements through detailed design information, structural calculations, fire performance evidence, BIM modelling, controlled manufacturing processes and documented project records.

For more information on the use of LGSF please consult Metsec Technical Guidance Note MET-TGD-04 Metframe & Higher Risk Buildings.

A boundary wall, or fire wall restraint system, is an engineered arrangement used where an external wall is required to resist the spread of fire to an adjacent building or relevant boundary. In single-storey steel framed buildings, this normally involves the primary frame, protected structural support members, secondary steelwork and fire-resisting external wall cladding working together to maintain an adequate load path in the fire condition.

Current BCSA guidance is based on a “capable member” concept, where the fire-resisting cladding is hung from a protected structural member designed to perform at elevated temperature. The intent is that the boundary elevation remains supported and approximately vertical, so that fire spread is resisted. Unprotected cold-formed side rails should not normally be relied upon to carry vertical cladding loads in the fire case, unless the members and their connections have been specifically designed for that condition.

For Metsec side rail systems, the side rails are generally intended to restrain the cladding against horizontal wind loading in normal design conditions. Where a boundary condition applies, the requirement should be identified early so that the protected capable member, cladding system, fixings, connections, fire protection and allocation of design responsibilities can be properly coordinated between the frame designer, steelwork contractor, secondary steelwork manufacturer and cladding manufacturer.

Yes. Metsec side rails can be used in an elevation that has a boundary wall condition, but their role must be correctly understood. In normal design conditions, side rails provide restraint to the external cladding and transfer horizontal wind loads back to the primary frame. In the fire case, they should not normally be relied upon to provide vertical support to the cladding or to define the fire resistance performance of the boundary wall.

Metsec’s Technical Guidance Note on Side Rails in Fire Boundary Conditions MET-TGD-02 explains that, for boundary elevations, the fire-resisting cladding should generally be supported from a suitably protected “capable member”, normally a dedicated protected hot rolled member provided as part of the fabricator’s package. The side rails are generally intended to restrain the cladding against horizontal wind load only and offer no additional vertical support during the fire case.

Where a boundary condition applies, it should be identified early so that the protected capable member, cladding system, fixings, load paths, fire protection and design responsibilities are coordinated between the relevant project parties. It should not be assumed that a boundary wall requirement can be resolved by changes to the secondary steel package alone.

No, not normally. MET-TGD-02 explains that slotted connections between side rails and the primary steelwork were historically used to allow for perceived thermal expansion in the fire case, often with combustible washers intended to permit bolt movement. However, this approach was based on an interpretation of fire test conditions rather than the current design guidance for boundary elevations.

The latest guidance from both BCSA and SCI is that slots need not be provided at the connections between the side rails and the primary steelwork. MET-TGD-02 also notes that side rails restrain the columns in normal design conditions, so introducing slots can be detrimental to their intended restraint function. Thermal movement in the fire case can generally be accommodated by thermal bowing of the side rails, and the use of slots was in any case limited by the cladding fixings, column stays and practical slot length.

Where a boundary wall condition applies, the critical requirement is not to introduce slotted side rail connections, but to ensure that the overall boundary elevation is properly designed. This includes the protected capable member, cladding support load path, connection design, fire protection, and coordination between the relevant project parties.

The fire resistance of a boundary elevation is not normally designed by one party in isolation. The BCSA Technical Specification for boundary elevations explains that implementation of a competent boundary solution requires coordination by the Principal Designer, because different design approaches place responsibilities on different parties. The primary frame must be designed to retain the elevation in the fire case, while the cladding system must provide the required resistance to fire penetration and heat transfer.

No. A Metsec eaves beam should not be used as the capable member in a boundary wall condition. Metsec’s position is that a dedicated protected hot rolled capable member should be provided for cladding support where a boundary wall condition applies, generally as part of the steelwork fabricator’s package.

This is because there is limited evidence available for protecting thin-gauge cold-formed steel for this function, and the level of board encasement likely to be required would generally make the solution impractical. In addition, the eaves beam is often located out of the plane of the cladding system, which can create unresolved load path issues. The capable member, protection system, support connections and cladding load path should therefore be identified and coordinated separately as part of the boundary elevation design.

Before specifying a boundary wall arrangement, the project team should confirm whether the elevation is in a boundary condition, the required period and direction of fire resistance, and the design approach being adopted for the primary frame, capable member, secondary steelwork and cladding system. This should be coordinated early by the Principal Designer, as the BCSA Technical Specification for boundary elevations notes that different solutions place responsibilities on different parties.

  • Whether the wall is within a boundary condition and whether fire resistance is required from the inside only or from both sides.
  • The required fire resistance period and the applicable project fire strategy, Building Regulations requirements and insurance or warranty requirements.
  • The design approach for the primary frame, including whether SCI P313 base moment guidance is being followed or whether each portal frame is protected to prevent collapse.
  • The location, type and protection method for the capable member, including whether intermediate capable members are required for tall elevations or discontinuous cladding arrangements.
  • The vertical load from the cladding and secondary steelwork to be carried by the capable member in the fire condition.
  • The cladding system fire resistance evidence, including testing to BS EN 1364-1 or BS 476-22 where applicable, and any engineering justification for the cladding being top-hung in the fire case.
  • The load path for vertical or horizontal cladding, including vertical secondary members where horizontal cladding is used.
  • The resistance of fixings, lap joints, cleats and support connections in the fire condition, particularly where elevated temperature significantly reduces connection capacity.
  • The allocation of design responsibilities between the Principal Designer, frame designer, steelwork contractor, secondary steelwork manufacturer, cladding manufacturer and main contractor.

Yes. Metsec mezzanine floor systems can be used as part of fire-rated floor constructions, where the required performance is supported by the relevant tested or assessed build-up. Metsec has fire tested standard mezzanine floor build-ups, providing evidence for commonly used floor protection arrangements.

The achievable fire rating depends on the complete floor construction, including the Metsec steel joists, decking, ceiling or board protection, fixings, penetrations and installation details. The required fire resistance period should be confirmed against the project fire strategy, Building Regulations requirements and the applicable Metsec test or assessment evidence before specification.

Environmental & Sustainability

100% of the steel sections can be recycled at the end of use or life.

The secondary material input of Metsec Purlins and Framing products is 12.8% based on Metsec EPD published 10 February 2023.

For Metsec Decarb products the secondary material input is 95.1% based on Metsec Decarb EPD published 7June 2024.

For Metsec Purlins and Framing the global warming potential is 2.76 kgCO2e based on Metsec EPD published 10 February 2023.

For Metsec Decarb products the lower GWP figure is 1.25 kgCO2e based on Metsec Decarb EPD published 7June 2024.

Quality, Health, Safety and the Environment are considered to be of utmost importance and voestalpine Metsec shall actively promote and administer a strong Quality, Health, Safety, Environmental and Ethical culture amongst staff, visitors and sub-contractors.

To assure these objectives are realised, voestalpine Metsec plc have established an Integrated Management System in accordance with PAS 99: 2012, which incorporates the requirements of BS EN ISO 9001 for Quality Management, BS EN ISO 14001 for Environmental Management, ISO 50001 for Energy Management, and ISO 45001 for Health & Safety Management.

Metsec Decarb incorporates steel produced using manufacturing processes designed to significantly reduce embodied carbon compared with conventional alternatives. Decarb solutions are available across Metsec product ranges, helping support project sustainability targets without compromising performance.

Yes. Purlins systems can support embodied carbon reduction strategies through efficient structural design, optimisation of material use and the availability of lower embodied carbon steel alternatives such as Metsec Decarb

Yes. Metsec provides Environmental Product Declarations for its purlins and framing products, including a third-party verified EPD for standard steel purlins and framing, and a separate EPD for Metsec Decarb purlins and framing. These declarations provide independently verified environmental impact data in accordance with recognised EPD standards and can be used to support embodied carbon assessments, specification decisions and project sustainability submissions.

The current Metsec EPD’s is available from the Metsec downloads area. Project teams should always use the latest published EPD applicable to the specified product range.

Warranty & Support

Yes. voestalpine Metsec carries professional indemnity insurance for its design-related activities. A copy of our £5m professional indemnity insurance certificate is available from the Metsec download area. Project teams should refer to the current published certificate for policy details, scope of cover and any applicable limitations.

Yes. Metsec provides technical support during the design phase for purlin, side rail and mezzanine floor projects. Support is available through Metsec’s sales and technical teams, with comprehensive technical support provided by the design office where project-specific input is required.

Engineers can also use Metsec’s published technical manuals, load tables and MetSPEC 14 design software to support section selection, system optimisation and design coordination. Final design responsibility, loading assumptions, restraint conditions, fixing requirements and project-specific compliance requirements should always be confirmed by the project engineer.

Purlins may appear to be commodity products, but design support, technical competence, manufacturing capability, logistics performance and long-term product availability all depend on the strength of the supplying organisation. Metsec combines UK manufacturing expertise with the backing of the global voestalpine Group.