Purlins Load Tables

The load tables contained in this document are the result of extensive design and testing using the facilities and skills of the Department of Mechanical Engineering at The University of Strathclyde.

Performance

The performance of the systems shown in this document has been derived by calculation in accordance with BS EN1993-1-3: 2006, calibrated and proven by full scale tests. Purlin load tables are valid up to and including 25° roof slopes. For slopes greater than 25 °, use our MetSPEC design software. You can download our MetSPEC software from our downloads centre.

Download our purlin technical manual for more information.

sleeved-side-rail-system-load-table

Tables are based on a deflection limit of Span/150 and adopt a cladding weight of 12.5kg/m² on elevation.

View load table

butt-side-rail-system-load-table

Tables are based on a deflection limit of Span/150 and adopt a cladding weight of 12.5kg/m² on elevation.

View load table